The Science behind Canoxidin®
Canoxidin: the premier, clinically validated solution for preventing complications associated with indwelling urological devices.
Canoxidin: the premier, clinically validated solution for preventing complications associated with indwelling urological devices.
The use of indwelled urological devices is frequently linked to a variety of clinical complications:
Patients prone to stone formation exhibit a higher susceptibility to these complications, and the risk of encrustation increases with the duration of device use (1). Statistical data indicates that among patients with long-term catheters, up to 70% experience CAUTIs and approximately 50% encounter catheter blockages (2).
Unique Combination of Active Ingredients
How Canoxidin Works to Prevent Stent Encrustation
Canoxidin uses a dual mechanism of action to reduce bacterial growth and prevent mineral deposits (encrustation) on urinary stents and other indwelling urological devices.
Process of Stent Encrustation
Canoxidin targets two critical steps in stent encrustation
Urine acidification (L-methionine) to reduce conditions that favour crystal formation
Crystal growth inhibition (phytate and theobromine) to prevent mineral deposition on the device.
Canoxidin works by interrupting the key steps that lead to catheter blockage and infection through a dual mechanism: urine acidification and inhibition of crystal formation.
Process of Encrustation
Catheter insertion introduces bacteria (with intermittent catheters, new contamination may occur at each catheterization).
Conditioning film formation occurs as proteins and organic molecules coat the catheter surface.
Bacterial adhesion by urease-producing organisms (e.g., Proteus, Klebsiella, and Morganella) raises urine pH (alkalinisation).
Canoxidin action: L-methionine acidifies the urine, counteracting this pH increase.
Bacteria-induced crystal deposition begins on the catheter surface.
Canoxidin action: Phytate and theobromine inhibit crystal formation and growth.
Without intervention, crystal buildup can lead to partial or complete catheter blockage, resulting in: Incomplete bladder emptying, Bacteriuria and Catheter-associated urinary tract infection (CAUTI).
Canoxidin targets two critical steps in encrustation
Helps prevent catheter encrustation by acidifying urine (L-methionine)
Inhibits crystal formation (phytate and theobromine), reducing the risk of blockage and subsequent catheter-associated urinary tract infections.
“These results demonstrate an 8-fold reduction in global encrustation for the [Canoxidin] experimental group, together with a striking reduction in the degree of such encrustation in every analysis, when considering distinct stent ends or the sum of all ends… The use of an oral composition [Canoxidin] in patients indwelling a double J ureteral stent resulted in fewer stent encrustations.” (11)
Torrecilla et al.,BMC Urol. 2020
This study of patients who had indwelling Foley catheters showed that Canoxidin® reduced the formation of encrustations (10-fold reduction) with an excellent short-term safety profile. (12)
Evidence from Borau et al., Actas Urol Esp., 2024